26-99-150MR - Electrochem, 3.6 Volt, 14 mAh Battery
Electrochem26-99-150MR$115.00SRP:Electrochem 26-99-150MR, 3.6V, 14mAh compatible battery for DigiTrak Supercell The Electrochem battery is a direct replacement for the Digital Control, DigiTrak Supercell Battery. Note: This is...
Description
Original code for Double C cell
Double C Replacement Lithium Battery for DitchWitch, DigiTrak SuperCell and Subsite HDD Sondes
Compatible with DigiTrak SuperCell, DitchWitch & Subsite HDD sonde Double C batteries
Note: This is not an original DCI battery
Double-C Specifications
Specs
Type: High Capacity Lithium Thionyl Chloride (LiSOCl2)
Voltage: 3.6 Volt
Capacity: 16 Ah
Cell Size: Double C
Diameter
Diameter: 26.2 mm
Length: 98 mm
Replacement battery for:
DigiTrak® SuperCell™
Electrochem 26-99-150MR Series: 4339
ER261020H
MaxHDD
HDD Power Cell
Understanding Passivation in Double-C Cells
Passivation is a phenomenon that all lithium primary cells experience, for more information please see our paper on "Passivation in Lithium Batteries for HDD Sondes".
- What is Passivation:
- Occurs in all lithium primary cells due to interaction between lithium anode and electrolyte.
- A thin layer forms instantly on the anode surface when electrolyte is added.
- This layer protects the anode and conserves active materials during storage, extending shelf life.
- Effects of Passivation:
- Normally does not degrade performance.
- If the layer becomes too thick (e.g., due to long storage or high temperature), it can impair discharge performance.
- Thick passivation can cause voltage delay—a lag between applying a load and voltage response.
- May show as a low battery reading or unacceptable voltage on a Transmitter Information Screen.
- Battery Behavior:
- Once installed and discharging, battery voltage typically rises to normal levels.
- Discharge helps break down the passivation layer, increasing porosity and power output.
- One Source Batteries (OSB) Specific Practices:
- Double C cells are De-Passivated every 6 months and tested before shipping.
- Recommended to install or maintain within 4 to 6 months after purchase.
- Installing after this window may show low voltage due to passivation.
- Passivation can be reversed by Depassivating the cell again.
- Installation Insight:
- Once a battery with acceptable voltage is installed, it starts discharging.
- When your Double C cell is installed the battery begins discharging and the lithium ions migrate through the battery, breaking down the passivation layer.
- This leads to full battery utilization and proper operation.
Notes
Battery life differs according to the transmitter being used, the materials and depths it is being used in.
A deeper depth transmitter will use more power than lower depth transmitters.
These batteries are designed to fit most all DigiTrak® transmitters and DitchWitch beacons.
Double-C Battery Test Fixture
DISCLAIMER
- This unit is designed for the Double C cells sold by One Source Batteries.
- It is sold only to customers who currently purchase Double C cells.
- Customers must have an online account established.
- To purchase this testing fixture, follow this link.
Introducing One Source Batteries Double-C Battery EOL Test Fixture
The Double-C EOL test fixture is a tool that will allow you to test batteries before they are installed in your DCI, Ditch Witch, Subsite or any other beacons using the Double C lithium batteries.
For more information on this test fixture for the One Source Batteries Double C cells, call us at (888) 321-9264 or email Support@OneSourceBatteries.com.
To purchase this test fixture use this link to see the terms of purchase.